V1.0.46(23/08/24) New Add firmware update support to cloud connected devices Bugfix Exflash raid driver improvements V1.0.45(21/05/24) New Set all LEDS on EOS at startup Bugfix Invert input alarm state for APDP only, so off = alarm off, on = alarm on V1.0.44(16/04/24) New Add cloud buffer when no connectivity Add configuration options for event log duplicate suppression and update help with more information Update reset source with more detail Security and performance improvements V1.0.43(13/02/24) New Add customer specific CB value when not present V1.0.42(15/01/24) New Update TFT alarms screen to display dynamically Bugfix Alarm on non-present APDP core temp Tidy up log-off flow APDP factory programming & initialization TFT not showing alarms and network when clustering enabled Clear orphan alarms if a device is deleted Year on data log graphs V1.0.41(06/12/23) New Enable logging of temp monitoring by default Bugfix Cloud enabled devices after reboot send incorrect message length TCB ordering for cloud Set active bank rather than leaving unknown in flash on first use of a unit Crash when no firmware is available in backup bank and revert firmware is used Digital input alarm state reporting incorrectly V1.0.40(04/10/23) Bugfix TFT not displaying past 9th cb group V1.0.39(27/09/23) New HWtest minor update Add support for APDP FCS with EWS Bugfix Factory serial update js V1.0.38(18/09/23) New Update UI for APDP and IO in groups Bugfix Local feed e2 driver possible corruption on raid repair V1.0.37(01/09/23) Bugfix APDP voltage calibration initialisation TH probes on DIO and small number of non grouped feeds not displaying summary info V1.0.36(31/08/23) New Update Web UI for sensors pages to group by ews and expansion and provide sensor summaries for Each device when collapsed Add all sensors page V1.0.35(25/08/23) New Update TFT UI Remove temp sensors from DIO when not present on PCB Bugfix Fix intermittent sensors not displaying on TFT V1.0.34(22/08/23) New feed.cgi interface adjustments, move units to headings and change colours and mouse dropdown on mouseover HWTest Updates for new PCB V1.0.33(27/07/23) New Add firmware updates for EOS-CT Configure alarms and descriptions to follow CT's when order is changed Add cloud interface Update display to support non grouped feeds V1.0.32(24/05/23) New Add order to feedTable in SNMP Rename IPDU-EOS to EOS-LCS Add support for EOS-CT Add extra warning when adding groups to cabinets - "Expected 6 groups per EOS Cabinet" Bugfix Limit expansion auto recovery frequency per hour V1.0.31(24/10/22) New Update default feed naming convention Add one calibration offset for internal use V1.0.30(04/10/22) Bugfix Fix grouping when full count of groups exist V1.0.29(29/09/22) New Remove Group prefix when a description is set. When not set add "Unnamed CB/Fuse Group" Provision for customer specific SNTP Leave the date set on factory reset Bugfix Resize columns to fit 16th character on TFT V1.0.28(21/09/22) New On LCD display, display order if no feed/group description is provided V1.0.27(13/09/22) New Update warning prompt when < 6 groups used Add button to auto populate descriptions where needed Update Feed to EOS on display where needed V1.0.26(08/09/22) New Total power consumption on diags page Bugfix Fix intermittent serial change V1.0.25(06/09/22) New Power Log Bugfix Unhide top table in factory use page V1.0.24(18/08/22) New SNMP write Heirarchy for 4 or more feeds Wildcard domains added to new certificate Enable IWDG earlier Enable no bootloader firmware Added ability to change factory defaults V1.0.23(18/05/22) New Allow concurrent voltage calibration on local feeds add support for ACEPDB and vastly increase information on factory page add default network control to factory settings Bugfix fix more than 6 DIO's displaying on the factory page V1.0.22(14/03/22) New Update data log settings messaging Bugfix Increase timeout of log downloads from 2 mins to 5 mins preventing full logs from finishing Fix error in data log js V1.0.21(11/03/22) Bugfix Fix data log frequency not saving until reboot V1.0.20(02/02/22) New Configure display to reset on startup if firmware update has not occurred Rename from "Multi Const" to "Shunt Amps Per Count" in feed calibration Change display backlight to use IOX rather than PWM Add node serial print dialogue Bugfix Fix EWS factory default multi's and offsets skipping the first 8 offsets intermittently Fix nominal current constant displaying incorrectly Increase reply message length when sending data1 messages V1.0.19(09/11/21) New Add extra accuracy to factory page Remove center alignment off selects Bugfix Fix power intermittently showing 0 in SNMP Fix display of feed without feed type set V1.0.18(11/08/21) New Move EoS cabinet controller outputs from LEDs to Relays Add , before cluster Bugfix Fix last char of serial not displaying for relay outputs V1.0.17(09/08/21) Bugfix Fix cabinet controller website display issues Fix copy to clipboard used in manufacturing V1.0.16(02/08/21) New Improve memory consumption of web server buffers Move SNMP memory to TCM Configure logoff to move all sessions to the logoff screen Order feeds on factory screen Bugfix Remove decimal place from Feeds with only one cluster in them Fix tripped breakers reporting intact on the tft display and current alarms persisting after being disabled until next reboot if tripped breaker is also enabled Fix validation on the factory screen Fix feed current total on dashboard and tft home page Clean extra characters at the end of log exports V1.0.15(26/07/21) New Add the ability to disable connection state changes on nodes Move EXP fields not relevant to customer to diags In SNMP, configure CB's, fuses, IO's to report as not present if device is disconnected (on top of entire device) Add additional diags page for sofware debugging Bugfix Data log frequency changes not applying until next reboot Feed detection not assigning letters and speed up process Emails dropping last character of the serial Duplicate and incorrect connectivity alerts when a EXP device is (dic)connected Data log device details getting chopped off V1.0.14(21/07/21) New Add circuit breaker and fuse status to data log V1.0.13(19/07/21) New Remember previous data log filters Allow EoS DIO to be joined to feed Bugfix Fix help page alignment Fix data log custom date filters EXP manual restart when auto recovery is enabled Add hardware change detected to replacing unknown event V1.0.12(08/07/21) New Populate feedClusterID in snmp Allow feedClusters with more than 2 members and set limit of 8 to number of feedClusters MIB version 2.4 which adds connectivity warning traps for EXP devices Update EoS counts per amp coeficcient Rename EWS Alarm X to EWS LED Alarm X on output dropdown Give comms LED a name under digital IO in the web interface Rename identity to feed name and fix full length feed names displaying an extra invalid character Move graph cache regen to another thread on cluster change operations Refresh screen on feed name change or description change so node heading is properly updated Feed current and voltage to factory page Copy EWS2 details to clipboard to factory page Configure LEDs in web interface for EoS Feed I2C addresses on diagnostics page Separate exp settings and exp firmware table Split firmware file selection and update into steps and add power warning Force display refresh parameter and configure for feed changes Ordering of feeds Dash in serials Increase memory to support 24 feeds EXP LED alarm, display alarm and dash alarm for disconnected EXP node EXP connectivity events, emails and traps EXP auto recovery EXP firmware retransmit on corrupt packet Bugfix Fix combination of clustered and unclustered feeds on the dashboard Fix feed calculations when feeds contain multiple clusters. Hardware revision check on expansion updates Fix bug where software version validation is invalid EXP device current calculation for data log V1.0.11(27/05/21) New Add support for leds over i2c Update SNMP to populate feedCurrentType and optimise message in feedProtXInfo Add blank state to tripped breakers when not connected to web interface Disable alarms to on EXP devices when not responding Increase device not responding threshold from 3 to 5 seconds Add tx of output state to DIO nodes for EoS Bugfix fix default all multis and offsets button not saving persistently Fix feedProtectionType in SNMP (critical) fix intermittent SMTP crash V1.0.10(21/05/21) New Configure applying firmware message to be persistent Add button on support page to reset EWS2 to virgin state Rename apdp OLED from Alarm U/NU to LED Alarm U/NU Create factory code V1.0.9(20/05/21) New Configure alarms on OLED for APDP based on users input Adjust APDP for INPUTs and RELAYs not connected V1.0.8(14/05/21) New Add input functions to APDP input table in web interface Add alarms to OLED for APDP Adjust APDPFCS nominal calibration constant for new shunt V1.0.7(11/05/21) New Add extra confirmation to apply firmware updates add revert firmware option V1.0.6(10/05/21) New Increase data log points from 10 to 40 Relabel CB to CB Current in data log V1.0.5(07/05/21) New Hard code APDP LCS LED and Relays Rename ARA to ARA LED and Power to Power LED V1.0.4(07/05/21) Bugfix Disable ADC AWD Fix invalid datalog erases V1.0.3(07/05/21) Bugfix Add extra debug information to startup events Stop more than 4 firmware retries without a cold boot V1.0.2(06/05/21) Bugfix Change IWDG libraries V1.0.1(06/05/21) New Rename Urg Relay to U Relay on OLED Add codes to startup events Bugfix Fix intermittent crashes due to graph generation triggering watchdog V1.0.0(05/05/21) New Set default voltage calibration points to 55 and 40V Add applying firmware to displays Set sntp to log after 3 failures rather than 1 Bugfix Set eula to appear for user accounts only Fix edge case in crc generator causing malformed firmware Fix intermittent crashes due to graph generation triggering watchdog V0.0.14(03/05/21) New Add colours and adjust limits per model of current and power gauges on homepage Bugfix Fix data log write bug causing sectors to get skipped intermittently Fix energy graphs last data point Fix firmware persistence V0.0.13(30/04/21) New Add calibration success events Change all nominal calibration factors to 1 and introduce per model calibration constants Bugfix Fix graph errors Fix ui bug preventing the saving of LED and RELAY outputs Fix feed busbar and core temps in SNMP Centre message div on system page V0.0.12(29/04/21) New Bugfix Fix voltage calibration for APDP LCS Fix energy calculation on dashboard V0.0.11(28/04/21) New Initial Release