Home > Support > Application Notes > Mini Balun Termination
Mini Balun Termination
Mini Balun termination in 4 simple steps:-
1. Fit the nut Tube assembly over the cable and strip as shown |
|
2. Fold the shield/screen/drain wire (if present) back over the cable. Insert the twisted pair into the stuffer cap. The stuffer cap hole with raised entry corresponds to the coax pin polarity. |
|
3. Dress the wires. Tuck the wire ends into the pockets provided then fold the screen and drain wire forward over the stuffer cap. |
|
4. Push the stuffer cap assembly onto the contacts and tighten the nut |
|